| Building Height | 12 meter clear height at eaves |
| Plinth Height | 1.27m height from dock apron finish level |
| Mezzanine Floor | Mezzanine of approx. 11,500 sq.ft. |
| FM2 Flooring | FM2 Flooring & 5 MT/M² Floor UDL to support high cube racking |
| Dock Doors | 50 Nos. loading docks (2 Nos. in each bay for faster loading and unloading of goods) with chequered plate in entire docking area |
| Structure | Pre-engineered building, optimized column spacing and mezzanine level for office |
| Bay Spacing | 8.00m side wall spacing, 16.00m centre spacing and 25.00m span |
| Walls | 3.0m high brick wall with external surface paint |
| Pitch of Roof | 1:10 slope as per design |
| Roofing | 0.55mm thick bare galvalume Standing Seam premium roofing system with 10 year leak-proof warranty & capable of taking solar panel load |
| Ventilation | Passive ventilation to provide 6 air changes. Louvers provided on external walls and no monitor on roof for air circulation |
| Rooftop Solar Panels | Provision for Rooftop Solar for discounted electricity to lessee |
| Cladding | 0.5mm thick color coated galvalume sheet |
| Natural Skylight | Vertical cliding 1 in each way |
| Internal and External LED Lighting | Energy saving and long life LED’s of branded Jaguar fitting |
| Canopy | 4.5m wide cantilever canopy on apron side & near entries offers protection from adverse weather conditions & adequate height clearance for tall trucks/trailers |
| 24.00m Wide Road With Apron | 24.00m wide concrete area from face of dock wall to edge for loading and unloading movements for truck & trailers |
| Dock Levellers | 10 Nos. dock levellers provided to address height difference between vehicles and loading platforms |
| Glass Wool Insulation | Fire resistant, 50mm thick glass wool insulation on roof and all sides with long, suitably laminated polypropylene based facing material (WMP-50) |
| Fire Fighting | Fire-fighting system with ceiling sprinklers, external and internal hydrants with complete fire compliance and NOC |
| Fire Exit | Fire exit at every 30 meters with fire resistant doors |
| Compliances | Fully compliant with Government Consents and Approvals. Fully compliant with MIDC sanction |