Building Specification

ParticularsDetails
Building Height12 meter clear height at eaves
Plinth Height1.27m height from dock apron finish level
Mezzanine FloorMezzanine of approx. 11,500 sq.ft.
FM2 FlooringFM2 Flooring & 5 MT/M² Floor UDL to support high cube racking
Dock Doors50 Nos. loading docks (2 Nos. in each bay for faster loading and unloading of goods) with chequered plate in entire docking area
StructurePre-engineered building, optimized column spacing and mezzanine level for office
Bay Spacing8.00m side wall spacing, 16.00m centre spacing and 25.00m span
Walls3.0m high brick wall with external surface paint
Pitch of Roof1:10 slope as per design
Roofing0.55mm thick bare galvalume Standing Seam premium roofing system with 10 year leak-proof warranty & capable of taking solar panel load
VentilationPassive ventilation to provide 6 air changes. Louvers provided on external walls and no monitor on roof for air circulation
Rooftop Solar PanelsProvision for Rooftop Solar for discounted electricity to lessee
Cladding0.5mm thick color coated galvalume sheet
Natural SkylightVertical cliding 1 in each way
Internal and External LED LightingEnergy saving and long life LED’s of branded Jaguar fitting
Canopy4.5m wide cantilever canopy on apron side & near entries offers protection from adverse weather conditions & adequate height clearance for tall trucks/trailers
24.00m Wide Road With Apron24.00m wide concrete area from face of dock wall to edge for loading and unloading movements for truck & trailers
Dock Levellers10 Nos. dock levellers provided to address height difference between vehicles and loading platforms
Glass Wool InsulationFire resistant, 50mm thick glass wool insulation on roof and all sides with long, suitably laminated polypropylene based facing material (WMP-50)
Fire FightingFire-fighting system with ceiling sprinklers, external and internal hydrants with complete fire compliance and NOC
Fire ExitFire exit at every 30 meters with fire resistant doors
CompliancesFully compliant with Government Consents and Approvals. Fully compliant with MIDC sanction